Procedure
1. Let the protection plates remain on the Flange Ball until welding is finished. These
plates protect the surface of the Flange Ball from welding sparks.
%
$
A. Protection plate
B. Flange Ball
2. Make sure that the Flange Ball is mounted in such a way that the grove is directed
upwards when the flange is mounted on the tank nozzle.
$
A. Groove
3. If the tank flange is inclined, make sure that the Flange Ball is welded so that the
Flange Ball is horizontal when it is mounted on the tank.
The tank flange inclination should not exceed 17 degrees.
60 mm
< 17°