Table 6-5: Measurement Status for the Rosemount 5900S
(continued)
Message
Description
Action
Predicted level
The presented level is predicted. The surface
echo could not be detected.
See No surface echo above.
Sampling failed
The sampling of the last tank signal failed.
Check Warning Messages.
Invalid volume value
The given volume value is invalid.
Check Volume Status for details.
Simulation Mode
The simulation mode is active. The presented
measurement values are simulated.
No action needed.
Advanced Simulation
Mode
The advanced simulation mode is active. The
given measurements are simulated.
To turn off the Advanced Simulation mode set
Holding Register 3600=0 (see
and holding registers using TankMaster
Tracking Extra Echo
The transmitter is in the empty tank state
tracking an extra echo.
Verify that the level gauge tracks the product
surface when the tank is filled.
Bottom Projection
Active
The bottom projection function is active.
Verify that the level gauge properly tracks the
product surface.
Pipe Measurement
Enabled
Pipe Measurement is active.
No action needed.
Surface close to
registered false echo
Close to a registered false echo measurement
accuracy may be slightly reduced.
By using the Register False Echo function the
transmitter can track the product surface in
the vicinity of disturbing objects.
Sudden level jump
detected
This may result from various measurement
problems.
Check interior of the tank to find out what
causes the problem tracking the surface.
Reference Manual
Service and troubleshooting
00809-0100-5900
September 2019
Rosemount 5900S Radar Level Gauge
213
Summary of Contents for Rosemount 5900S Series
Page 1: ...Reference Manual 00809 0100 5900 Rev EA September 2019 Rosemount 5900S Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5900 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5900 12 Reference Manual ...
Page 182: ...Configuration Reference Manual September 2019 00809 0100 5900 182 Reference Manual ...
Page 186: ...Operation Reference Manual September 2019 00809 0100 5900 186 Reference Manual ...
Page 266: ...Product Certifications Reference Manual September 2019 00809 0100 5900 266 Reference Manual ...