Ui (Vmax)
Ii (lmax)
Pi
Ci
Li
Entity parameters
30 V
300 mA
1.3 W
1.1 nF
1.5 µH
FISCO parameters
17.5V
380 mA
5.32 W
1.1 nF
1.5 µH
Special Conditions for Safe Use (X):
1. See certificate for special conditions.
B.13
Republic of Korea
B.13.1
IP Korea Intrinsic Safety
Certificate
14-KB4BO-0573X
Markings
Ex ia IIC T4 Ga/Gb
(-50 °C ≤ Ta ≤ +80 °C)
Ui (Vmax)
Ii (lmax)
Pi
Ci
Li
Entity parameters
30 V
300 mA
1.3 W
1.1 nF
1.5 µH
FISCO parameters
17.5V
380 mA
5.32 W
1.1 nF
1.5 µH
Special Conditions for Safe Use (X):
1. See certificate for special conditions.
B.14
Additional Certifications
B.14.1
Functional Safety Certification (SIS)
3 Functional Safety
Certificate
ROS 1312032 C001
SIL 3 2-in-1 (1oo2) option (SIS-relays)
Standards
IEC 61508:2010 Parts 1-7
S Functional Safety
Certificate
ROS 1312032 C004
SIL 2 1-in-1 (1oo1) option, with 4-20mA or K1/K2 relay
Standards
IEC 61508:2010 Parts 1-7
Certificate
ROS 1312032 C005
SIL 2 2-in-1 (1oo1) option, with 4-20mA or K1/K2 relay
Standards
IEC 61508:2010 Parts 1-7
Product Certifications
Reference Manual
September 2019
00809-0100-5900
260
Reference Manual
Summary of Contents for Rosemount 5900S Series
Page 1: ...Reference Manual 00809 0100 5900 Rev EA September 2019 Rosemount 5900S Radar Level Gauge ...
Page 6: ...Contents Reference Manual September 2019 00809 0100 5900 vi Reference Manual ...
Page 12: ...Introduction Reference Manual September 2019 00809 0100 5900 12 Reference Manual ...
Page 182: ...Configuration Reference Manual September 2019 00809 0100 5900 182 Reference Manual ...
Page 186: ...Operation Reference Manual September 2019 00809 0100 5900 186 Reference Manual ...
Page 266: ...Product Certifications Reference Manual September 2019 00809 0100 5900 266 Reference Manual ...