Inspection, Maintenance and Adjustment
4-73
DX380LC-7
18. Renew the O-ring on the centrifugal oil cleaner housing
cover. Tighten the locknut.
Oil Bath Precleaner (If Equipped) - Clean
The lower parts of the body assembly must be inspected each
time the air cleaner is serviced. If there is any sign of buildup or
plugging, the body assembly must be removed and cleaned.
At least once a year, remove body assembly and perform the
following service steps:
1.
Remove oil cups (3 and 4) and removable filter (2).
2.
Clean the inner oil cup (3) and outer oil cup (4).
3.
Reassemble inner cup in outer cup and refill both cups to
indicated oil level (9.5 liters). The same oil specified for the
engine crankcase is generally acceptable.
4.
Inspect filter with a light. Hold it up to a bright light. An
even, bright pattern of light should show through the wire
element, meaning it is clean.
20 N.m
DS2000321
Figure 104
Figure 105
FG018320
1
2
3
4
Reference
Number
Description
1
Precleaner Housing
2
Screen Filter
3
Inner Oil Cup
4
Outer Oil Cup
Figure 106
FG018321