2-55
DX380LC-7
2)
Max. E/G Limit
The maximum engine rpm can be set.
The configurable max. engine rpm range varies
depending on the machine.
How to access: User Menu
→
Attachment
Management
→
One Way/Two Way Setting
→
Max. E/G Limit
How to change the maximum engine rpm
–
After setting the new rpm and pushing
'OK', the change of maximum engine rpm
is complete.
–
Default setting: 1800
NOTE:
The maximum engine rpm
setting resolution is 50 rpm.
3)
Min. Flow
The minimum flow rate can be set.
How to access: User Menu
→
Attachment
Management
→
One Way/Two Way Setting
→
Min. Flow
How to change the minimum flow
–
After setting the new flow and pushing 'OK',
the change of minimum flow is complete.
–
Default setting: 30
NOTE:
The minimum flow rate can be
set below the maximum flow
rate in units of 10 lpm.
4)
Max. Flow
The maximum flow rate can be set.
How to access: User Menu
→
Attachment
Management
→
One Way/Two Way Setting
→
Max. Flow
How to change the maximum flow
–
After setting the new flow and pushing 'OK',
the change of maximum flow is complete.
–
Default setting: 245
NOTE:
The maximum flow rate can be
set from the minimum flow rate
up to 1,000 lpm in units of 5 lpm.
Figure 108
DS1900345
DS1900347
Figure 109
DS1900346
Figure 110