DX380LC-7
A.
One Way/Two Way Select
This menu allows you to choose between five
settings saved in the one way/two way settings.
How to access: User Menu
→
Attachment
Management
→
One Way/Two Way Select
The maximum flow rate and pressure for an
attachment are displayed to the right of the name of
the attachment.
B.
One Way/Two Way Setting
This menu allows you to set up to five settings to use
with the one-way/two-way option.
How to access: User Menu
→
Attachment
Management
→
One Way/Two Way Setting
The following items can be set.
•
Max. Press.
•
Max. E/G Limit
•
Min. Flow
•
Max. Flow
•
Button Type
•
Change Name
1)
Max. Press.
The maximum pressure can be set.
The configurable max. pressure range varies
depending on the machine.
How to access: User Menu
→
Attachment
Management
→
One Way/Two Way Setting
→
Max. Press.
How to change the maximum pressure
–
After setting the new pressure and
pushing 'OK', the change of maximum
pressure is complete.
–
Default setting: 340
NOTE:
The maximum pressure
indication/setting resolution is
10 bar.
Figure 105
DS1901956
Figure 106
DS1900343
DS1901271
Figure 107