DX380LC-7
Operation
3-76
Pump Display and Control Elements of
Control Screen
The display and control unit is protected from water splashes
and mechanical damage by a transparent plastic cover. The
cover must be removed to program the unit and then remounted
afterwards.
Display and Control Elements
Representation
Description
Function
Three-digit LED display
Values and operating status
Pause LED
Interval time
Contact LED
Display contact time (pump operation)
1 = CS LED
Monitors system function by an external piston
detector
CS = Cycle Switch, piston detector
2 = PS LED Monitors function with an external
pressure switch
PS = Pressure Switch
Fault LED
Fault notification
UP or DOWN key
•
Switch on display
•
Display values and parameters
•
Set values and parameters
SET key
•
Switch between programming mode and
display mode
•
Confirm values
DK key
•
Trigger interim lubrication
•
Delete fault notification
CS
PS