System Management
375
DELL CONFIDENTIAL – PRELIMINARY 9/13/06 – FOR PROOF ONLY
User Guidelines
•
The following algorithm is used to select a unit as the master:
–
If only one master-enabled unit is in the stack (1 or 2), it becomes the master.
–
If a unit configured as a forced master, it becomes the master.
If a forced master unit is removed from a stack and placed in a different stack with another
forced master unit, both are considered to be forced, and the election criteria continue as
follows:
–
The unit with the longer up-time is elected master. Units are considered to have the same
up-time if they were powered up within ten minutes of each other.
–
If both forced master units have the same up-time, Unit 1 is elected.
Example
The following example selects Unit 2 as the stack master.
stack
r
eload
The
stack reload
Privileged EXEC mode command reloads stack members.
Syntax
stack reload
[
unit
unit
]
•
unit—
Number of the unit to be reloaded (Range: 1-6)
Default Configuration
All units are reloaded.
Command Modes
Privileged EXEC mode
User Guidelines
If no unit is specified, all units are reloaded.
Example
The following example reloads Unit 2 of the stack.
Console(config)#
stack master unit
2
Console(config)#
stack reload
unit
2