Syntax
rmon alarm
index variable interval rthreshold fthreshold revent fevent
[
type
type
] [
startup
direction
] [
owner
name
]
no rmon alarm
index
•
index
— Specifies the alarm index. (Range: 1-65535)
•
variable
— Specifies the object identifier of the particular variable to be sampled.
•
interval
— Specifies the interval in seconds during which the data is sampled and
compared with rising and falling thresholds. (Range: 1-4294967295)
•
rthreshold
— Specifies the rising threshold. (Range: 0-4294967295)
•
fthreshold
— Specifies the falling threshold. (Range: 0-4294967295)
•
revent
— Specifies the event index used when a rising threshold is crossed.
(Range: 1-65535)
•
fevent
— Specifies the event index used when a falling threshold is crossed.
(Range: 1-65535)
•
type
— Specifies the method used for sampling the selected variable and calculating the
value to be compared against the thresholds. Possible values are
absolute
and
delta
.
If the method is
absolute
, the value of the selected variable is compared directly with the
thresholds at the end of the sampling interval. If the method is
delta
, the selected
variable value of the last sample is subtracted from the current value, and the difference
is compared with the thresholds.
•
direction
— Specifies the alarm that may be sent when this entry is first set to valid.
Possible values are
rising
,
rising-falling
and
falling
.
If the first sample (after this entry becomes valid) is greater than or equal to
rthreshold
and
direction
is equal to
rising
or
rising-falling
, a single rising alarm is generated. If the
first sample (after this entry becomes valid) is less than or equal to
fthreshold
and
direction
is equal to
falling
or
rising-falling
, a single falling alarm is generated.
•
name
— Specifies the name of the person who configured this alarm. If unspecified, the
name is an empty string.
Default Configuration
The type is
absolute
.
The startup direction is
rising-falling
.
Command Mode
Global Configuration mode
User Guidelines