234
PHY Diagnostics Commands
www
.dell.com | support.dell.com
DELL CONFIDENTIAL – PRELIMINARY 9/13/06 – FOR PROOF ONLY
Examples
The following examples display the optical transceiver diagnostics.
Console#
show fiber-ports optical-transceiver
Power
Port
Temp
Voltage
Current
Output
Input
TX Fault
LOS
----
----
-------
-------
------
-----
-------
---
1/g1
W
OK
E
OK
OK
OK
OK
1/g2
OK
OK
OK
OK
OK
E
OK
1/g3
Copper
Temp – Internally measured transceiver temperature.
Voltage - Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured TX output power.
Input Power – Measured RX received power.
Tx Fault – Transmitter fault
LOS – Loss of signal
N/A - Not Available, N/S - Not Supported, W - Warning, E - Error
Console#
show fiber-ports optical-transceiver detailed
Power
Port
Temp
Voltage
Current
Output
Input
TX Fault
LOS
[C]
[Volt]
[mA]
[mWatt] [mWatt]
----
----
-------
-------
------
-----
-------
---
1/g1
48
5.15
50
1.789
1.789
No
No
1/g2
43
5.15
10
1.789
1.789
No
No
1/g3
Copper
Temp – Internally measured transceiver temperature.
Voltage - Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured TX output power.
Input Power – Measured RX received power.
Tx Fault – Transmitter fault
LOS – Loss of signal