Install logs
•
Core files
•
Details on the CNA or Fabric Adapter Ethernet interface, including IP address and mask.
•
Status and states of all adapter ports, including the Ethernet, FCoE, and DCB ports on CNAs
and Fabric Adapters.
•
DCB status and statistics for CNAs and Fabric Adapters
•
Network driver information, Ethernet statistics, offload parameters, and flow control coalesce
parameters for CNAs and Fabric Adapters.
•
Ethernet offload and flow control parameters for CNAs and Fabric Adapters.
NOTE
Before collecting data through the Support Save feature, you may want to disable auto-recovery on
the host system. When adapters are reset after an auto-recovery from a failure, traces initiated
before the failure may be lost or overwritten.
To disable auto-recovery, use the following commands:
•
For Linux, use the following commands, then reboot the system:
-
To disable auto-recovery for the network (BNA) driver.
insmod bna.o bnad_ioc_auto_recover=0
-
To disable auto-recovery for the storage (BFA) driver.
insmod bfa.o ioc_auto_recover=0
•
For VMware, use the following commands.
-
To unload and load the network (BNA) driver with IOC auto-recovery disabled, use the
following commands:
esxcfg-module -u bna
esxcfg-module bna bnad_ioc_auto_recover=0
-
To disable IOC auto-recovery for the network (BNA) driver across reboots, use the following
command:
esxcfg-module -s "bnad_ioc_auto_recover=0" bna
-
To disable IOC auto-recovery for the storage (BFA) driver across reboots, use the following
command:
esxcfg-module -s "ioc_auto_recover=0" bfa
•
For Windows use the Registry Edit tool (regedt32) or the BCU drvconf --key command.
Following is the drvconf ---key command:
bcu drvconf --key ioc_auto_recover --val 0
•
For Solaris, edit /kernel/drv/bfa.conf using the following command:
ioc-auto-recover=0
NOTE
Brocade 804 and 1007 adapters are not supported on Solaris systems.
Summary of Contents for Brocade 825
Page 4: ......
Page 10: ...x Brocade Adapters Installation and Reference Manual 53 1002144 01 ...
Page 28: ...xxviii Brocade Adapters Installation and Reference Manual 53 1002144 01 ...
Page 82: ...54 Brocade Adapters Installation and Reference Manual 53 1002144 01 Using BCU commands 1 ...
Page 92: ...64 Brocade Adapters Installation and Reference Manual 53 1002144 01 Mezzanine adapters 2 ...
Page 230: ...202 Brocade Adapters Installation and Reference Manual 53 1002144 01 Regulatory compliance 5 ...
Page 264: ...236 Brocade Adapters Installation and Reference Manual 53 1002144 01 List of Acronyms C ...