Select the second logical operator to be used on the boolean input calculated in par. 13-40, 13-41, and 13-42,
and the boolean input coming from par. 13-42.
[13-44] signifies the boolean input of par. 13-44.
[13-40/13-42] signifies the boolean input calculated in par. 13-40, 13-41, and 13-42. DISABLED [0] (factory
setting). select this option to ignore par. 13-44.
[0]
*
DISABLED
[1]
AND
Evaluates the expression [13-40/13-42] AND [13-44].
[2]
OR
Evaluates the expression [13-40/13-42] OR [13-44].
[3]
AND NOT
Evaluates the expression [13-40/13-42] AND NOT [13-44].
[4]
OR NOT
Evaluates the expression [13-40/13-42] OR NOT [13-44].
[5]
NOT AND
evaluates the expression NOT [13-40/13-42] AND [13-44].
[6]
NOT OR
Evaluates the expression NOT [13-40/13-42] OR [13-44].
[7]
NOT AND NOT
Evaluates the expression NOT [13-40/13-42] and evaluates AND NOT [13-44].
[8]
NOT OR NOT
Evaluates the expression NOT [13-40/13-42] OR NOT [13-44].
13-44 Logic Rule Boolean 3
Array [6]
[0]
False
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
[24]
Comparator 1
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
FC 300 Programming Guide
2. How to Programme
MG.33.M3.02 - VLT
®
is a registered Danfoss trademark
137