[3]
Motor speed
Motor speed
[3] [RPM] or [Hz]
[4]
Motor current
Motor current
[4] [A]
[5]
Motor torque
Motor torque
[5] [Nm]
[6]
Motor power
Motor power
[6] [kW] or [hp]
[7]
Motor voltage
Motor voltage
[7] [V]
[8]
DC-link voltage
DC-link voltage
[8] [V]
[9]
Motor thermal
Motor thermal
[9] Expressed as a percentage.
[10]
VLT thermal
VLT thermal
[10] Expressed as a percentage.
[11]
Heat sink temp.
Heat sink temp
[11] Expressed as a percentage.
[12]
Analog input AI53
Analog input AI53
[12] Expressed as a percentage.
[13]
Analog input AI54
Analog input AI54
[13] Expressed as a percentage.
[14]
Analog input AIFB10
Analog input AIFB10
[14] [V]
[15]
Analog input AIS24V
Analog input AIS24V
[15] [V] Analog input AICCT [17] [°].
[17]
Analog input AICCT
[18]
Pulse input FI29 (FC
302 only)
Pulse input FI29 (FC 302 Only)
[18] Expressed as a percentage.
[19]
Pulse input FI33
Pulse input FI33
[19] Expressed as a percentage.
[20]
Alarm number
Alarm number
[20] The error number.
[30]
Counter A
Counter A
[30] Number of counts
[31]
Counter B
Counter B
[31] Number of counts
[50]
False
False
[50] Enters the fixed value of false in the comparator.
[51]
True
True
[51] Enters the fixed value of true in the comparator.
[52]
Control ready
Control ready
[52] The control board receives supply voltage
[53]
Drive ready
Drive ready
[53] The frequency converter is ready for operation and applies a supply signal on the control board.
[54]
Running
Running
[54] The motor is running.
[55]
Reversing
Reversing
[55] The output is high when the frequency converter is running counter clockwise (the logical product
of the status bits “running” AND “reverse”)
[56]
In range
In range
[56] The motor is running within the programmed current and speed ranges set in par. 4-50 to par.
4-53.
[60]
On reference
On reference
[60] The motor is running on reference.
[61]
Below reference, low
Below reference, low
[61] The motor is running below the value given in par. 4-54 “Warning Reference Low”
[62]
Above reference, high
Above reference, high
[62] The motor is running above the value given in par. 4-55 “Warning Reference High”
[65]
Torque limit
Torque limit
[65] The torque limit, set in par. 4-16 or 4-17, has been exceeded.
[66]
Current limit
Current limit
[66] The motor current limit, set in par. 4-18, has been exceeded.
[67]
Out of current range
Out of current range
[67] The motor current is outside the range set in par. 4-18.
[68]
Below I low
Below I low
[68] The motor current is lower than set in par. 4-50.
[69]
Above I high
Above I high
[69] The motor current is higher than set in par. 4-51.
[70]
Out of speed range
Out of speed range
[70] The speed is outside the range set in par. 4-52 and 4-53.
[71]
Below speed low
Below speed low
[71] The output speed is lower than the setting in par. 4-52.
[72]
Above speed high
Above speed high
[72] The output speed is higher than the setting in par. 4-53.
[75]
Out of feedb. range
Out of feedb. Range
[75] The feedback is outside the range set in par. 4-56 and 4-57.
[76]
Below feedb. low
Below feedb. Low
[76] The feedback is below the limit set in par. 4-56.
[77]
Above feedb. high
Above feedb. High
[77] The feedback is above the limit set in par. 4-57.
[80]
Thermal warning
Thermal warning
[80] The thermal warning turns on when the temperature exceeds the limit in the motor, the
frequency converter, the brake resistor or thermistor.
[82]
Mains out of range
Mains out of range
[82] The mains voltage is outside the specified voltage range.
[85]
Warning
Warning
[85] A warning is active.
[86]
Alarm (trip)
Alarm (trip)
[86] A (trip) alarm is active.
FC 300 Programming Guide
2. How to Programme
MG.33.M3.02 - VLT
®
is a registered Danfoss trademark
131
2