5-71 Term 32/33 Encoder Direction
Option:
Function:
Change the detected encoder rotation direction without changing the wiring to the encoder.
[0]
*
Clockwise
Sets channel A 90° (electrical degrees) behind channel B upon clockwise rotation of the encoder shaft.
[1]
Counter clockwise
Sets channel A 90° (electrical degrees) ahead of channel B upon clockwise rotation of the encoder shaft.
This parameter cannot be adjusted while the motor is running.
2.8.9. 5-9*Bus Controlled
This parameter group selects digital and relay outputs via a fieldbus setting.
5-90 Digital & Relay Bus Control
Option:
Function:
[0]
*
0 - FFFFFFFF
This parameter holds the state of the digital outputs and relays that is controlled by bus.
A logical '1' indicates that the output is high or active.
A logical '0' indicates that the output is low or inactive.
Bit 0
Digital Output Terminal 27
Bit 1
Digital Output Terminal 29
Bit 2
Digital Output Terminal X 30/6
Bit 3
Digital Output Terminal X 30/7
Bit 4
Relay 1 output terminal
Bit 5
Relay 2 output terminal
Bit 6
Option B Relay 1 output terminal
Bit 7
Option B Relay 2 output terminal
Bit 8
Option B Relay 3 output terminal
Bit 9-15
Reserved for future terminals
Bit 16
Option C Relay 1 output terminal
Bit 17
Option C Relay 2 output terminal
Bit 18
Option C Relay 3 output terminal
Bit 19
Option C Relay 4 output terminal
Bit 20
Option C Relay 5 output terminal
Bit 21
Option C Relay 6 output terminal
Bit 22
Option C Relay 7 output terminal
Bit 23
Option C Relay 8 output terminal
Bit 24-31
Reserved for future terminals
5-93 Pulse Output #27 Bus Control
Range:
Function:
0%
*
[0.00 - 100.00%]
Set the output frequency transferred to the output terminal 27 when the terminal is configured as 'Bus Controlled'
in par. 5-60 [45].
5-94 Pulse Output #27 Time-out Preset
Range:
Function:
0.00%
*
[0.00 - 100.00%]
Set the output frequency transferred to the output terminal 27 when the terminal is configured as 'Bus Ctrl
Timeout' in par. 5-60 [48]. And a time-out is detected.
5-95 Pulse Output #29 Bus Control
Range:
Function:
0%
*
[0.00 - 100.00%]
Set the output frequency transferred to the output terminal 29 when the terminal is configured as 'Bus Controlled'
in par. 5-60 [45].
This parameter only applies for FC 302.
5-96 Pulse Output #29 Time-out Preset
Range:
Function:
0.00%
*
[0.00 - 100.00%]
Set the output frequency transferred to the output terminal 29 when the terminal is configured as 'Bus Ctrl
Timeout' in par. 5-60 [48]. And a time-out is detected.