Par. 4-19 cannot be adjusted while the motor is running.
4-20 Torque Limit Factor SourceOption
Option:
Function:
Select an analog input for scaling the settings in par. 4-16 and 4-17 from 0% to 100% (or inverse). The signal
levels corresponding to 0% and 100% are defined in the analog input scaling, e.g. par. group 6-1*. This pa-
rameter is only active when par. 1-00
Configuration Mode
is in
Speed Open Loop
or
Speed Closed Loop
.
[0]
*
No function
[2]
Analog input 53
[4]
Analog input 53 inv
[6]
Analog input 54
[8]
Analog input 54 inv
[10]
Analog input X30-11
[12]
Analog input X30-11
inv
[14]
Analog input X30-12
[16]
Analog input X30-12
inv
4-21 Speed Limit Factor SourceOption
Option:
Function:
Select an analog input for scaling the settings in par. 4-19 from 0% to 100% (or inverse). The signal levels
corresponding to 0% and 100% are defined in the analog input scaling, e.g. par. group 6-1*. This parameter
is only active when par. 1-00
Configuration Mode
is in
Torque Mode
.
[0]
*
No function
[2]
Analog input 53
[4]
Analog input 53 inv
[6]
Analog input 54
[8]
Analog input 54 inv
[10]
Analog input X30-11
[12]
Analog input X30-11
inv
[14]
Analog input X30-12
[16]
Analog input X30-12
inv
2.7.3. 4-3* Motor Feedback Monitoring
The parameter group includes monitoring and handling of motor feedback devices as encoders, resolvers etc.
4-30 Motor Feedback Loss Function
Option:
Function:
Select which reaction the frequency converter should take in the case a feedback fault is detected. The selected
action will take place if the feedback signal differs from the output speed with more than specified in par. 4-31
during the time set in par. 4-32.
[0]
Disabled
[1]
Warning
[2]
*
Trip