Removing a Stuck Plate From the Output Device
81
CAUTION:
Use caution when handling the powerful magnetic trailing-edge
clamps used to hold the media on the imaging drum.
•
Operators with implanted cardiac pacemakers should ensure that
magnetic clamps are kept more than 2.75" (7 cm) away from their
pacemaker.
•
When handling the magnetic clamps, do not bring opposite poles near
each other. Keep hands and fingers from between opposite magnetic
poles.
•
Always wear protective gloves when handling magnetic clamps.
If you have additional concerns, consult your physician and/or the
manufacturer of your implant.
CAUTION:
Keep magnetic data—floppy disks, magnetic stripe cards, watches,
etc.—away from the powerful magnetic trailing-edge clamps.
To remove a plate from the drum:
1.
Open the top and front access panels.
See
Opening and Closing the Front Access Panel
2.
Put on protective gloves.
Protective gloves should be clean and lint-free to ensure the interior of
the output device is kept clean.
CAUTION:
Plate edges are sharp. Failure to wear protective gloves can
result in personal injury.
3.
If the plate is held by the trailing-edge clamps, slide the clamps off the
plate. Otherwise, skip this step.
Summary of Contents for Trendsetter 3244+ AL
Page 2: ......
Page 3: ...Trendsetter 3244 AL version TS8 Operator Manual ...
Page 4: ......
Page 10: ...viii Trendsetter 3244 AL Operator Manual ...
Page 30: ...16 Chapter 1 System Overview ...
Page 69: ...Replacing the Mylar Strip 55 ...
Page 70: ...56 Chapter 3 Maintenance ...
Page 102: ...88 Chapter 4 Troubleshooting ...
Page 103: ...Part Numbers Parts List 90 ...
Page 111: ...External Laser Safety Labels 97 Figure 44 Non interlocked Panel Danger label ...
Page 122: ...108 Appendix B Labels ...
Page 126: ...112 Appendix C Regulatory Compliance ...
Page 132: ...118 Trendsetter 3244 AL Operator Manual ...
Page 133: ......
Page 134: ...www creo com www Creo com ...