Error Messages and Recommended Solutions
71
Error Category: Hardware
Error Message
Recommended Operator Action
External debris blower
filter not present.
1.
Shut down the output device.
2.
Check to make sure there is a filter installed correctly in
the debris removal cabinet. See
3.
If the filter is in place, call your service representative to
report the problem.
External debris blower
filter full.
•
Replace the debris filter. See
External debris blower
filter almost full.
•
Replace the debris filter. See
External debris blower
system blocked (high
vacuum).
1.
Shut down the output device.
2.
Open the debris removal cabinet and check for
obstructions to vacuum hoses.
External debris blower
system not connected (low
vacuum).
1.
Shut down the output device.
2.
Check power supply to cabinet.
3.
Check that serial cable is properly connected.
Summary of Contents for Trendsetter 3244+ AL