Chapter 4– Troubleshooting
Error Category: SCSI
Error Message
Recommended Operator Action
SCSI bus reset while
imaging.
[Error #: 21000]
1.
In the Suspend dialog box on the workstation, click either the
Resume
or
Cancel Image
button.
The Trendsetter should recover from this error automatically.
The medium in the output device, however, will be marked as a
reject.
2.
Call your service representative to report the error.
SCSI parity error while
imaging. Check plate for
artifacts.
[Error #: 21001]
1.
Check the medium for image artifacts.
2.
If you find image artifacts, or if you think artifacts might be
on the medium but are not visible, re-image the medium.