Error Messages and Recommended Solutions
73
Focus error detected at
<distance> inches while
imaging
check plate for artifacts.
[Error #: 17664]
This error can be caused by:
•
dents in a plate
•
improperly loaded medium
•
an image running off the edge of the medium (that is, the
image is wider than the medium)
To correct the error:
1.
Inspect the medium closely for image artifacts.
2.
Try imaging again using a new medium of the correct
size.
Important:
If the error persists, call your service
representative.
Incorrect light level at
start of edge detection.
Check plate if plate size
entered too small.
[Error #: 17731]
1.
Make sure the medium was loaded in the correct position
on the load ramp.
2.
Check the plate type information to ensure the medium
size stated in the workstation software matches the size
you loaded.
3.
If the medium sizes match:
In the Suspend dialog box on the workstation, click the
Resume
button to resume imaging.
Or:
If the medium sizes don’t match:
Click the
Cancel Image
button in the Suspend dialog box,
and modify the media size as needed.
Or:
Load a different-sized medium into the output device.
Or:
Reload the medium.
Error Category: Head
Error Message
Recommended Operator Action
Summary of Contents for Trendsetter 3244+ AL
Page 2: ......
Page 3: ...Trendsetter 3244 AL version TS8 Operator Manual ...
Page 4: ......
Page 10: ...viii Trendsetter 3244 AL Operator Manual ...
Page 30: ...16 Chapter 1 System Overview ...
Page 69: ...Replacing the Mylar Strip 55 ...
Page 70: ...56 Chapter 3 Maintenance ...
Page 102: ...88 Chapter 4 Troubleshooting ...
Page 103: ...Part Numbers Parts List 90 ...
Page 111: ...External Laser Safety Labels 97 Figure 44 Non interlocked Panel Danger label ...
Page 122: ...108 Appendix B Labels ...
Page 126: ...112 Appendix C Regulatory Compliance ...
Page 132: ...118 Trendsetter 3244 AL Operator Manual ...
Page 133: ......
Page 134: ...www creo com www Creo com ...