28
Chapter 2 – Operation
Media Registration
Media alignment labels should be affixed to the load table and manual
bypass tray of your output device during installation. If they were not, you
can affix the labels to the output device yourself (with the kind assistance
of your service representative). These labels act as guidelines to help you
align the media during loading. The output device’s laser does the more
precise registration. The laser beam corrects the registration to within 15 µ
(micron) if you:
•
load the media to within ±0.125" (3 mm) of the correct position on the
load table/manual bypass tray. If affixed, the media alignment labels
can help you quickly identify the correct position.
•
ensure the media are resting on the registration pins at the base of the
load table/manual bypass tray. These pins ensure the media registers
properly on the drum.
Performing these steps can result in faster overall imaging time, as
detection of the media edge occurs more quickly.
Plate Bending and Punching
Ensure your existing plate bending and punching equipment is configured
to match registration points on your output device. For additional
information, contact your service representative.
Summary of Contents for Trendsetter 3244+ AL
Page 2: ......
Page 3: ...Trendsetter 3244 AL version TS8 Operator Manual ...
Page 4: ......
Page 10: ...viii Trendsetter 3244 AL Operator Manual ...
Page 30: ...16 Chapter 1 System Overview ...
Page 69: ...Replacing the Mylar Strip 55 ...
Page 70: ...56 Chapter 3 Maintenance ...
Page 102: ...88 Chapter 4 Troubleshooting ...
Page 103: ...Part Numbers Parts List 90 ...
Page 111: ...External Laser Safety Labels 97 Figure 44 Non interlocked Panel Danger label ...
Page 122: ...108 Appendix B Labels ...
Page 126: ...112 Appendix C Regulatory Compliance ...
Page 132: ...118 Trendsetter 3244 AL Operator Manual ...
Page 133: ......
Page 134: ...www creo com www Creo com ...