62
Chapter 4– Troubleshooting
Table 5: Error Category: No Category
Error Category: (No category)
Error Message
Recommended Operator Action
Air supply below threshold.
[Error #: 19000]
Contaminants have damaged the air system in the output
device or otherwise restricted airflow.
1.
Check your air supply system.
2.
Call your service representative immediately to report
the error.
Resolution specified is not
available.
[Error #: N/A]
You may have the Trendsetter configured to use resolutions
that are not available.
To correct the error:
•
Configure the workstation software to use a valid
resolution.
Resume or clear received when
not suspended.
[Error #: N/A]
You can safely ignore this message.
Too many characters in
command string.
[Error #: N/A]
Ensure the computer serial interface is connected to the
correct port on the workstation.
Workstation communications
lost.
[Error #: 21]
This error is reported every 30 seconds while it persists.
To correct the error:
1.
Ensure the computer serial interface is connected to the
correct port on the workstation.
2.
If the cable is connected properly, reboot the
workstation.
3.
Shut down the output device.
4.
Start the output device.
5.
Start the workstation software.
Important:
If the error persists, contact your service
representative.
Summary of Contents for Trendsetter 3244+ AL
Page 2: ......
Page 3: ...Trendsetter 3244 AL version TS8 Operator Manual ...
Page 4: ......
Page 10: ...viii Trendsetter 3244 AL Operator Manual ...
Page 30: ...16 Chapter 1 System Overview ...
Page 69: ...Replacing the Mylar Strip 55 ...
Page 70: ...56 Chapter 3 Maintenance ...
Page 102: ...88 Chapter 4 Troubleshooting ...
Page 103: ...Part Numbers Parts List 90 ...
Page 111: ...External Laser Safety Labels 97 Figure 44 Non interlocked Panel Danger label ...
Page 122: ...108 Appendix B Labels ...
Page 126: ...112 Appendix C Regulatory Compliance ...
Page 132: ...118 Trendsetter 3244 AL Operator Manual ...
Page 133: ......
Page 134: ...www creo com www Creo com ...