Chapter 4– Troubleshooting
Table 9: Error Category: Head
Error Category: Head
Error Message
Recommended Operator Action
Break detected, exposure head
has reset.
[Error #: 17021]
1.
Shut down the output device.
2.
Reboot the workstation and workstation software.
3.
Start the output device.
4.
Even if the Trendsetter recovers from the error, call your
service representative to report it.
Couldn’t find plate edge due
to dirty edge strip on drum.
[Error #: 17013]
This message is displayed when an edge-detection strip is too
dirty to perform a proper medium edge detection.
Depending on the severity of the problem, the output device
may succeed if you try to resume the operation.
To try the edge detection again:
1.
Clean the edge-detection strips.
2.
In the message box on the workstation, click the
Resume
button.
The message box closes, and the output device tries the
edge detection procedure again. If the retry fails as well,
the Suspend dialog box is displayed again.
Important:
If the edge detection fails again after you clean
the edge detection strip, call your service representative to
report the error.
Summary of Contents for Trendsetter 3244+ AL
Page 2: ......
Page 3: ...Trendsetter 3244 AL version TS8 Operator Manual ...
Page 4: ......
Page 10: ...viii Trendsetter 3244 AL Operator Manual ...
Page 30: ...16 Chapter 1 System Overview ...
Page 69: ...Replacing the Mylar Strip 55 ...
Page 70: ...56 Chapter 3 Maintenance ...
Page 102: ...88 Chapter 4 Troubleshooting ...
Page 103: ...Part Numbers Parts List 90 ...
Page 111: ...External Laser Safety Labels 97 Figure 44 Non interlocked Panel Danger label ...
Page 122: ...108 Appendix B Labels ...
Page 126: ...112 Appendix C Regulatory Compliance ...
Page 132: ...118 Trendsetter 3244 AL Operator Manual ...
Page 133: ......
Page 134: ...www creo com www Creo com ...