68
Chapter 4– Troubleshooting
Timeout waiting for load
button to pressed.
[Error #: 15250]
A manual bypass job had been started but the Start button
was not pressed within the two-minute timeout period.
To correct the error:
1.
In the Suspend dialog box on the workstation, click the
Resume
button.
2.
Place the plate on the manual bypass tray.
3.
Press the Start button on the operator interface.
Unload carriage not in safe
position to rotate cups.
[Error #: 15306]
The unload table traveller was not able to find the rotate
position. The plate may have become stuck in the clamps,
causing the traveller to lose steps and not reach the rotate
position.
To correct the error:
1.
In the Suspend dialog box on the workstation, click the
Resume
button.
2.
When the plate is unloaded, check it for damage.
3.
Resubmit the job and try again.
Error Category: Auto Loader (ALE)
Error Message
Recommended Operator Action
Summary of Contents for Trendsetter 3244+ AL
Page 2: ......
Page 3: ...Trendsetter 3244 AL version TS8 Operator Manual ...
Page 4: ......
Page 10: ...viii Trendsetter 3244 AL Operator Manual ...
Page 30: ...16 Chapter 1 System Overview ...
Page 69: ...Replacing the Mylar Strip 55 ...
Page 70: ...56 Chapter 3 Maintenance ...
Page 102: ...88 Chapter 4 Troubleshooting ...
Page 103: ...Part Numbers Parts List 90 ...
Page 111: ...External Laser Safety Labels 97 Figure 44 Non interlocked Panel Danger label ...
Page 122: ...108 Appendix B Labels ...
Page 126: ...112 Appendix C Regulatory Compliance ...
Page 132: ...118 Trendsetter 3244 AL Operator Manual ...
Page 133: ......
Page 134: ...www creo com www Creo com ...