3C
Programming the Generator
CPI Canada Inc.
Page 3C-2
Rev. B Millenia / Indico 100 Series Service Manual Ch # 740904-05
3C.1.0 INTRODUCTION
Programming of the generator is performed using the operator control console. All programming menus
are displayed in the LCD display window on the console. The ten “soft key” buttons (1 to 10 in the figure
below) are used to navigate through the programming screens and to select and enter values in this
section.
In this section, SELECT means to press the button adjacent to the desired function shown in the
LCD display window
3C.1.1 Entering Into Programming Mode
To enter into the programming mode for the generator follow the steps below. Refer to figure 3C-1 for the
button locations referenced in this section. This figure depicts both the 23 X 56 (cm) console, and the 31 X
42 (cm) console.
1
4
5
8
RE SE T
2
3
9
10
6
7
Figure 3C-1: Programming/calibration mode reference
Step
Action
Result
1.
Start with the generator switched OFF.
2.
While pressing and holding the RESET
button, press the generator POWER ON
button on the console.
The generator will go through its start-up
sequence, then display the message
ENTER PASSWORD.
3.
Enter the password by pressing the button
sequence: [1] - [8] - [4] - [5].
The GENERATOR SETUP menu will now
be displayed as shown in the next
section.