323
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity ID
ETH Stack
Filters
Set
HW Error
Detected
Cause: Incoming
traffic causes ETH
Stack Filters to
malfunction.
Remedy: If the
hardware
supports stack
filters reset,
normal operations
continue.
Otherwise, the
unit will reboot.
This alarm is
triggered when
the ETH Stack
Filters
hardware
detects an
internal error.
Major
97000
ETH Stack
Filters
Clear
Fault Cleared
–
The fault is
cleared when
the detected
hardware error
is resolved.
Major
97000
D/R in
Progress
Set
Disaster declared
Cause: One or
more of the
following is
detected: RF lock
loss, unstable RF
signal, and/or
transport loss (RF
locked, but no
transport stream
packet received)
Remedy: A valid
signal.
A disaster is
detected.
Major
970
D/R in
Progress
Reset
No disaster
–
Disaster
recovery
feature is
cleared with a
valid signal.
Major
970