Chapter 5 Web GUI Setup and Monitoring
250
Choose
Manual Data1
or
Manual Data2
to only use DATA1 (port 1) or DATA2
(port 2) for output data. The remaining redundancy controls below are not
applicable.
Choose
Backup: Primary Data1
(default) or
Backup: Primary Data2
to use port 1
or port 2 as the primary data port and if a physical connectivity loss occurs, it
will failover to port 2 or port 1 (the backup port).
Choose
Mirroring
to send the same data to both port 1 and port 2. The remaining
redundancy controls below are not applicable.
3
If
Backup: Primary Data1/Data2
is selected as the
Mode
, choose the redundancy
Direction
. Select
Revertive
to attempt to revert back to the primary port when
using the backup port and the primary port is active again. Choose
Non-
Revertive
to always use the backup port, regardless of the condition of the
primary port.
4
In the
Delay Forward
field, set the time to switch the data port after the system
detects a failure, in a range from 0 to 10000 milliseconds.
5
In the
Delay Back
field, set the time to wait when reverting back to the primary
port once the primary link is active again, in a range from 1 to 120 seconds.
Note:
If
Non-Revertive
is selected as the
Direction
, this field does not apply.
6
Click
Apply
.
Viewing the Redundancy Status
The
Redundancy Status
table displays the latest redundancy status change.
The
Ports In Use
column displays the current output port in use (Data1 or Data2),
the
Change Reason
column displays a description of the reason for the last
redundancy status change (Link or Setup+Link), and the
Change Date & Time
column displays the last date and time the redundancy status changed.
Viewing the Link Status
The
Link Status
table displays the port information, such as the status speed,
duplex, and crossover. Port 1 is the management port and port 2 is the data port.
Summary of Contents for D9824
Page 22: ......
Page 26: ...Chapter 1 Introduction 4 On Screen Display support on baseband output NIT Retune Recovery ...
Page 40: ......
Page 164: ......
Page 306: ......
Page 368: ......
Page 370: ......
Page 388: ......
Page 410: ...Appendix C Compliance 388 Declarationof Conformity ...
Page 415: ......