Configuring Transport Stream Information
215
12
From the Category drop-down list, choose the category or service to configure. If
an input service matches this type and Instance, then the Action will be applied.
This value is only used if the Action is set to Map. The categories are: UNKN,
CDT, LSDT, DATA, TTX, MPE, DPI, VBI, SUBT, AUD, VID, PCR or INVL.
13
In the
Instance field
, enter the instance (1 to 64) of the service specified by
Category
to configure. If an input service matches this type and instance, then
the
Action
will be applied.
14
If
Action
is set to
Map
, enter the
Output PID
number (0 to 8192) in the
Output
PID
field.
15
Click
Save
.
16
Click
OK
.
To remove a PID mapping, click the radio button of the entry you want to
remove and click
Delete
.
Synchronizing the Inputs
1
In the
DPM Program Entry Setup
table, each PE output can be synchronized to
its input according to one of the four output modes. Select the program entry
you want to synchronize and then click
Resynchronize
or click
Resynchronize
All
to synchronize the inputs to the outputs according to the service assignments
only. The Confirm Resynchronization window is displayed.
2
Select whether you want to synchronize the PE output according to the services
and then the PIDs assigned to each service, services only, PIDs only, or to
synchronize using a template.
Map Mode
Description
Resynchronize Program, PMT
PID, ES List & ES PIDs
The receiver will synchronize the PE output according to
the services and then the PIDs assigned to each service.
Resynchronize ES List
The receiver will synchronize the PE output according to
the available input services only, and ignore the input to
output service PID mapping.
Resynchronize ES PIDs
The receiver will synchronize the PE output according to
the input PIDs only, and ignore the service assignment
categories/names.
Summary of Contents for D9824
Page 22: ......
Page 26: ...Chapter 1 Introduction 4 On Screen Display support on baseband output NIT Retune Recovery ...
Page 40: ......
Page 164: ......
Page 306: ......
Page 368: ......
Page 370: ......
Page 388: ......
Page 410: ...Appendix C Compliance 388 Declarationof Conformity ...
Page 415: ......