Chapter 5 Web GUI Setup and Monitoring
242
6
Choose
Transport Stream
>
Digital Program Mapping
for
ASI Output
or
MPEG over IP Output
. The ASI or MPEGoIP Digital Program Mapping page is
displayed.
7
In the DPM Program Entry Setup table, click
Resynchronize All
and click the
Resynchronize Program
,
PMT PID
,
ES List & ES PIDs
radio button and click
OK
. This copies the input services PIDs to the remapped output service PIDs.
8
In the DPM Program Entry Setup table, choose the PE containing the channel
you want to configure and click
Edit
. The DPM PE PID MAP window is
displayed.
9
Click
Add Row
.
10
From the
Action
drop-down list, choose Pass, Drop, or Map.
11
Choose the input to output channel mapping from the
Category
drop-down list.
Video and PCR can be output on the same PID or different PIDs. If output on the
same PID, they will appear identical to the input.
12
Click
Save
.
13
Click
OK
.
14
In the
DPM General Setting
area, choose the following parameters:
Setting
Parameter
Remapping Mode
Svc ID & PID
Duplication Method
Pkt Copy
Unreferenced Content
Drop
Service ID Output
Valid Ch/All Ch
PSI Table Output Option
Ctl By Table
PSI Regeneration Option
Always/As Needed
15
Click
Table Options
. The DPM Table Options window is displayed.
16
Set the following parameters:
Parameter
Description
PAT
Regen
CAT
Regen
PMT
Regen
TSDT
Drop
NIT
Regen or Drop
NITO
Drop
SDT
Regen
SDTO
Drop
BAT
Drop
Summary of Contents for D9824
Page 22: ......
Page 26: ...Chapter 1 Introduction 4 On Screen Display support on baseband output NIT Retune Recovery ...
Page 40: ......
Page 164: ......
Page 306: ......
Page 368: ......
Page 370: ......
Page 388: ......
Page 410: ...Appendix C Compliance 388 Declarationof Conformity ...
Page 415: ......