321
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity ID
FEC FPGA
Status
Set
FEC FPGA failed
to start
Cause: Hardware
issue.
Remedy: Ensure
that the USB Flash
is installed,
formatted, and the
image is loaded.
Also, ensure that
the FEC FPGA is
installed and the
CPLD is properly
programmed.
FEC FPGA is
loaded, but
failed to start
(not ready).
Major
92400
FEC FPGA
Status
Set
FEC FPGA access
failed
Cause: Hardware
issue.
Remedy: Ensure
that the USB Flash
is installed,
formatted, and the
image is loaded.
Also, ensure that
the FEC FPGA is
installed and the
CPLD is properly
programmed.
FEC FPGA is
loaded and
started, but
attempt to read
configuration
registers failed.
Major
92400
FEC FPGA
Status
Set
FEC FPGA
initialization failed
Cause: Hardware
issue.
Remedy: Ensure
that the USB Flash
is installed,
formatted, and the
image is loaded.
Also, ensure that
the FEC FPGA is
installed and the
CPLD is properly
programmed.
FEC FPGA is
loaded and
started, but
initial
parameter
setup failed.
Major
92400
FEC FPGA
Status
Clear
FEC FPGA is
running OK
–
FEC FPGA is
loaded, started,
initialized, and
is fully
operational.
Major
92400
Summary of Contents for D9824
Page 22: ......
Page 26: ...Chapter 1 Introduction 4 On Screen Display support on baseband output NIT Retune Recovery ...
Page 40: ......
Page 164: ......
Page 306: ......
Page 368: ......
Page 370: ......
Page 388: ......
Page 410: ...Appendix C Compliance 388 Declarationof Conformity ...
Page 415: ......