Chapter 6 Service and Maintenance
314
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity ID
FPGA
Temperature
Alarm
Set
Temperature over
Alarm threshold
Cause: Room
temperature too
high, or air flow is
blocked.
Remedy: Check
openings on front
and rear panels for
blockage. Lower
room temperature
or improve air
flow to device.
FPGA
temperature is
above safe
operating
range.
Major
30000
FPGA
Temperature
Alarm
Clear
Temperature
normal
–
–
Major
30000
ASI Out Status Set
ASI Overflow.
Output Muted.
Reduce content.
Cause: Uplink
settings may have
changed since
setup of the unit.
Variable Bit
Rate/Statmuxed
streams may be in
use.
Remedy: Increase
the output rate,
drop unreferenced
content in DPM
Options, and/or
drop programs
not needed for
downstream
devices. Contact
your (uplink)
service provider to
verify the
expected bit rate
settings.
Current
transport rate
exceeds
configured rate
for ASI output.
Output has
been muted to
protect
downstream
devices.
Minor
34000
ASI Out Status Clear
ASI Output
Restored
–
–
Minor
34000