Configuring Transport Stream Information
239
Svc ID
Description
All Ch
Transmits the PSI tables for the mapped program even if the
program does not exist in the input stream.
All Ch is only valid if the PAT, NIT, SDT and PMT are set to
Regenerate.
6
From the
SI Regeneration Option
drop-down list, choose the SI regeneration
option. This applies the PowerVu rates (consistent with the uplink). This
parameter is only used if
Remapping Mode
is set to None. The following table
describes each PSI rate:
PSI Rate
Description
Auto
Matches the generated PSI tables' output rate as the incoming rate.
MPEG Min
Transmits the generated PSI tables on the longest intervals that are
allowed by MPEG standard.
SA Std
Transmits the generated PSI tables based on PowerVu standard
intervals.
7
The
PSI Table Output Option
drop-down list allows the operator to specify
which PSI tables to include in the program/output stream. The following table
describes each option:
PSI Options
Description
Pass All
Transmits the incoming PSI Tables as is; does not modify the
content and rate.
Drop All
Does not transmit any PSI Tables.
Ctl By Table
The operator can click Table Options to select the output mode for
each table. The default table selections will be all pass, and only
with CDT dropped.
8
From the
PSI Regeneration Option
drop-down list, choose whether to
regenerate the PSI tables. You can select Always or As Needed (only if the
content has changed).
Summary of Contents for D9824
Page 22: ......
Page 26: ...Chapter 1 Introduction 4 On Screen Display support on baseband output NIT Retune Recovery ...
Page 40: ......
Page 164: ......
Page 306: ......
Page 368: ......
Page 370: ......
Page 388: ......
Page 410: ...Appendix C Compliance 388 Declarationof Conformity ...
Page 415: ......