Configuring Transport Stream Information
213
Configuring the DPM ASI Details
Note:
The following procedure defines all the available fields. For a typical setup of
the DPM, see
Typical set up for Digital Program Mapping (DPM)
(on page 241).
Note:
After you make any changes, a successfully updated (session open) message
appears. The changes are displayed, but not saved. You must click
Apply
to save
and apply the changes.
1
From the user interface of the D9824, choose
Transport Stream
>
Digital
Program Mapping
under
ASI Output
. The ASI Digital Program Mapping page
is displayed.
2
For each DPM
Program Entry
, it displays the input channel number (
Chl #
) and
channel name (
Name
). There are 32 channels (PE1 to PE32).
Note:
Any changes made to the ASI DPM values will automatically change the
Mode Status
to
Edited by User
in the ASI Outputs page.
3
In the table, select a program entry row you want to edit.
From the
Action
drop-down list, choose the DPM program action for the PE
(Pass, Map, or Drop).