311
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity ID
Flash Sector
Error
Set
Check setting.
Counted
<number> events
on <device>.
Cause: A sector on
FLASH on
<device> (Pri,
Sec,Trans 1, or
Trans 2) was
found corrupted
at power on,
which was not a
result of an
interrupted erase.
The problem
happened
<number> of
times on this
FLASH during a
lifetime.
Remedy: Check if
the desired
application is
running and if the
settings are valid.
FLASH
recovered after
unexpected
corruption.
Minor
25500
Signal Quality Set
Audio Muted due
to RF noise
Cause: RF Signal
quality is poor due
to interference or
signal level issues.
Remedy: Check
RF settings, re-aim
dish, and add
signal amplifier.
Signal is locked
but BER is
beyond Audio
muting
threshold.
Minor
26000
Signal Quality Set
Unstable RF
Signal
Cause: RF Signal
quality is poor due
to interference or
signal level issues.
Remedy: Check
RF settings, re-aim
dish, and add
signal amplifier.
Signal lock
status is
toggling
frequently.
Minor
26000