Chapter 6 Service and Maintenance
296
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity ID
PE n: Loss of
Input
Clear
Fault reset
–
–
Minor
11000
12000
13000
14000
15000
16000
17000
18000
18009-18032
Digital
Program
Mapping
Set
PID Collision
Cause: Uplink
settings may have
changed since
setting up the unit.
Please check your
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink
to find the
appropriate
system settings.
Two source
service PIDs
are being
mapped to the
same output
PID. This will
cause data
corruption in
the stream.
Minor
19000
Digital
Program
Mapping
Set
Program Collision Cause: Uplink
settings may have
changed since
setting up the unit.
Please check your
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink
to find the
appropriate
system settings.
Two source
channel
numbers are
being mapped/
passed to the
same channel
number in the
output.
Minor
19000
Digital
Program
Mapping
Set
Mode-i PMT out
of range
Cause: Uplink
settings may have
changed since
setting up the unit.
Please check your
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink
to find the
appropriate
system settings.
PMT PID to be
used for Mode-
i is outside of
valid MPEG
PID range.
Major
19000
Summary of Contents for D9824
Page 22: ......
Page 26: ...Chapter 1 Introduction 4 On Screen Display support on baseband output NIT Retune Recovery ...
Page 40: ......
Page 164: ......
Page 306: ......
Page 368: ......
Page 370: ......
Page 388: ......
Page 410: ...Appendix C Compliance 388 Declarationof Conformity ...
Page 415: ......