Section 3: Operation
Roadie HD+35K User Manual
3-57
020-100340-02 Rev. 1 (01-2010)
PIP Image Settings Secondary Menu
Adjust the PIP (secondary image) without affecting the size or position. The primary image remains
unchanged. Refer to
Section 3.6.3 Image Settings Menu
for details.
PIP Border Width
Set the desired line thickness for your PIP window border.
PIP Border Color
Select the desired color for the PIP window border.
Image Optimization AND Fade Time
NOTE:
These features are not available in this projector.
Numbers Select Main Image
Select the
Numbers Select Main Image
option to use the
numeric keys #1-8 as Input keys. This remapping of the “lite”
remote (refer to
Figure 3-32
) can be particularly useful with PIP
displays, providing a convenient shortcut for changing the
primary (background) image without first having to return to the
Main
menu. To use the keys in this manner all of the time, even
with single displays, select Always. For normal remote function,
select
Never
(default). Set to
When PIP Active
to activate
number keys as Input keys only when PIP is in use.
NOTE:
Numbers Select Main Image remote functionality works
only when menus are closed.
3.10 Working with the Lamp
Four different sized lamps can be used with this projector: 2, 3, 4.5 or 6 kW. To ensure that the required
ignition and power level is supplied to the lamp, you must define which lamp size is installed before power-up,
otherwise the lamp could be seriously overdriven or under driven. Subsequent adjustments in the Lam
p
menu
can then help to optimize lamp performance and ensure the brightest, most uniform image possible for the life
of the lamp.
3.10.1 Which Lamp is Installed?
The ideal time to check your lamp size is prior to each power up. This avoids the possibility of igniting your
lamp with the wrong level of power:
Refer to
Figure 3-34
. Before powering up the projection head, press
M
ENU
. The
LCD STATUS DISPLAY
at the
rear of the projector shows a "Lamp Size" of 2000, 3000, 4500 or 6000 watts, depending on its most recent
setting (factory default=6000). Select the lamp that is currently installed. If you are unsure, a Christie
accredited service technician must unlock the lamp door, and look at the lamp.