3-80
Roadie HD+35K User Manual
020-100340-02 Rev. 1 (01-2010)
Section 3: Operation
Table 3.9 System Error Codes
Code
Description
GENERAL
12
Software error. Contact dealer/factory.
13
CRC error in flash ROM. Download new software.
14
Engineering-only programming is complete. Call Christie, replace TIPM.
15
Attempting to download s/w code without being in boot mode
16
Invalid interrupt. Power off/on. If persists, contact dealer/factory.
17
User has forced system to stay in boot mode
18
Attempting to program boot mode without jumper
LAMP / BALLAST
20
The lamp is unexpectedly on (likely a ballast and/or wiring problem)
22
One or more high-current lamp cables is not connected
26
Lamp door is open (interlock)
27
Lamp cannot ignite
28
Lamp has turned off unexpectedly
29
Lamp ballast is overheated
2C
Lamp communications fault; ballast is not detected
SENSORS for COOLING
40
Lamp has shut down due to fan failure
46
The red TEC (DMD) has overheated
48
The blue TEC (DMD) has overheated
49
The prism has overheated
4C
Projector has shut down due to critical error
4D
Integrator has overheated
4E
Inadequate lamp air intake rate (interlock)
4F
Inadequate air exhaust rate (interlock)
FANS (note: there are no Fans 1 or 2 in this projector)
53
Fan 3 has failed (side [rear] intake fan)
54
Fan 4 has failed (side [front] intake fan)
55
Fan 5 has failed (lamp exhaust fan)
56
Fan 6 has failed (LAD fan)
57
Fan 7 has failed (card cage fan)
58
Fan 8 has failed (heat exchanger fan — for liquid cooling system)