4-8
Roadie HD+35K User Manual
020-100340-02 Rev. 1 (01-2010)
Section 4: Maintenance
8. Make sure that the anode (+) lead between lamp and Igniter is well away from any projector metal, such as
the reflector or firewall.
Leads too close to metal parts will cause arcing during starting pulse. This is
a Safety Hazard, and the lamp may not ignite.
9. Re-install the cooling compartment door and close the lamp compartment door.
NOTE:
The projector will not operate unless the louvered lamp compartment door is locked shut.
10. With a blue dot label or dry-erase pen, mark the lamp door's
LAMP INSTALLED
label to indicate the size of
the newly installed lamp - 2.0, 3.0, 4.5, or 6.0 kW. A supply of blue dot labels is secured inside the front
cover of this manual.
Figure 4-3 Always Mark the "Lamp Installed" Label (
EXAMPLE
)
11. Re-connect the projection head and the ballast to AC (refer to
Section 2.1 Projector Quick Setup and
Installation
), and then set the breaker/power switch to ON.
12. Set proper
Lamp Type
(
M
ENU
).
NOTE:
Not required if your new lamp is the
same Lamp Size
(in kilowatts) as the previous lamp.
If your new lamp is rated higher or lower than the old lamp, record the new Lamp Size (2.0, 3.0, 4.5 or 6.0
kW) in projector memory as described below. This setting establishes the proper range of power available
for the installed lamp, ensuring that the new lamp is neither underpowered nor over-driven upon power-up.
Do not attempt to ignite the lamp until its size (kW) is correctly defined in
projector memory.
Refer back to
Figure 3-33
.
a.
Press
M
ENU
. The
Status Display
at the rear of the projector shows a "Lamp Size" of 2000, 3000, 4500,
or 6000 (Factory default) watts, depending on its last setting.
b. Enter either the
Lamp Password
shown in
Figure 3-34
, or the Christie service password. A password
is required unless the "Enable Password" service option has been turned off.
c.
Use the
R
IGHT
and
L
EFT
Arrow keys to locate and select which lamp is currently installed. Make sure
the lamp type is also indicated on the lamp door label as shown in
Figure 4-3
.
d. When the
Status Display
shows the correct lamp type, the projector and lamp can be turned on.
13. Press
P
OWER
on any keypad/remote to power up the projector and ignite the lamp. Wait approximately 10
minutes for the projector and lamp to warm up before continuing.