5-54
COPYRIGHT © CANON ELECTRONICS INC. 2018 CANON DR-G2140/G2110/G2090 FIRST EDITION
CHAPTER 5 TROUBLESHOOTING
Adjustment procedure
i) Remove the eject tray unit and upper
front cover.
ii) Loosen the fixing screw
1
, rotate the
adjusting screw
2
and after moving
the sensor mounting plate
3
on
which the pickup sensor is mounted a
little back and forth, fix the plate.
Note:
The positioning boss
4
must be in-
serted into the hole in the sensor
mounting plate.
Figure 5-601
iii) While feeding a sheet of paper, check
the sensor and the feeding operation. If
it is not corrected, retry the previous
procedure.
iv) If it is corrected, replace covers and
check the operation again.