COPYRIGHT © CANON ELECTRONICS INC. 2018 CANON DR-G2140/G2110/G2090 FIRST EDITION
3-41
CHAPTER 3 DISASSEMBLY & REASSEMBLY
4. Power PCB
1) Remove 8 screws
1
(M4-bind head,
round tip) and pull out the power PCB
2
(including the mounting plate).
Figure 3-705
2) Remove the cable
1
(with a connector
lock) and cable
2
, then remove the power
PCB
3
(including the mounting plate).
Figure 3-706
3) Remove 6 screws
1
(M3-bind head,
round tip) and cable
2
(with connector
lock), and then remove the power PCB
3
.
Figure 3-707