4-26
4.13 X-cutter Unit
4.13.1 Installing the Leaf Switch F Assy
1. Attach the Leaf switch F assy to the Tape sensor holder with the Leaf switch F
screw.
Tape sensor lever
X-cutter unit
Sensor holder
Sensor holder screw
Leaf switch F screw
Leaf switch F assy
Fig. 4.13-1
Installing the Leaf Switch F Assy
4.13.2 Installing the X-cutter Unit
Slide the X-cutter unit into position from the right side of the main unit and fasten it in
position with the two X-cutter screws.
X-cutter unit
X-cutter screws
Fig. 4.13-2
Installing the X-cutter Unit