7.5 Troubleshooting
Flowcharts
AC adaptor plugged in, power ON
Nothing happens when power switch is
pressed.
b. Ab5V DC supply.
c. Defective main CPU.
See page 7-5.
No
Yes
Is POWER LED indicator lit?
Nothing happens when switches are pressed
(LED indicators do not light).
a. Defective switch or push switch on the
Switch PCB.
b. Defective LED on the Switch PCB.
See page 7-6.
Yes
No
Error at power ON
(red indicator flashes)
Yes
No
Before film feed?
An error occurred during processing after power
ON (before film feed).
a. Ab24V DC supply
b. Abnormal DC input voltage.
c. Abnormal X-cutter power ON processing.
d. Abnormal Y-carriage power ON processing.
e. Abnormal Y-cutter power ON processing.
See page 7-8.
An error occurred during processing after
power ON (after film feed).
a. Defective film or cartridge.
b. Defective film feed detector (TPS) switch.
c. Defective film feed system.
See page 7-10.
No
Yes
Is manual feed normal?
Nothing happens when switches are pressed
(LED indicators do not light).
a. Defective switch or push switch on the
Switch PCB.
b. Defective LED on the Switch PCB.
See page 7-6.
Abnormal manual feed .
a. Defective film feed (LF) motor.
b. Defective film compression system.
c. Problem related to paper eject roller.
See page 7-11.
ERROR LED (red) flashes
a. Abnormal input voltage.
Summary of Contents for LX-1200
Page 1: ...SERVICE MANUAL MODEL LX 1200 LX 300 ...
Page 2: ...COOL LAMINATOR SERVICE MANUAL MODEL LX 1200 LX 300 ...
Page 5: ...Chapter 1 SPECIFICATIONS ...
Page 9: ...Chapter 2 MECHANISMS ...
Page 20: ...Chapter 3 DISASSEMBLY PROCEDURES ...
Page 58: ...Chapter 4 ASSEMBLY PROCEDURES ...
Page 105: ...Chapter 5 ELECTRONIC CONTROLLERS ...
Page 127: ...Chapter 6 MAINTENANCE ...
Page 149: ...Chapter 7 TROUBLESHOOTING ...