5-10
5.4 Detector
Circuits
These circuits detect the status of the switches and keys that operate the machine
(Two-connection switch, Start key, Stop key, Dial switch, Continuous key, and Extra
border key) and the sensors that determine the film type, document length and width,
and cover open/closed status.
The circuits that detect each switch and sensor are listed below.
In addition, a separate switch to detect the motor initial status is also mounted.
•
Switch scan circuit
Two-connection switch, Continuous key, Extra
border key, Start key, and Stop key
•
Dial switch circuit
RSW1
•
RSW2 switches
•
Cover switch circuit
Cover switch
•
Paper width detector circuit
YCA-F sensor
•
Paper length detector circuit
PST switch
•
Cartridge type detector circuit CSIZE3
•
CSIZE4 switch
•
Film type detector circuit
ENC sensor
•
Film feed detector circuit
TPS switch
•
Input voltage detector circuit
ACV signals
Summary of Contents for LX-1200
Page 1: ...SERVICE MANUAL MODEL LX 1200 LX 300 ...
Page 2: ...COOL LAMINATOR SERVICE MANUAL MODEL LX 1200 LX 300 ...
Page 5: ...Chapter 1 SPECIFICATIONS ...
Page 9: ...Chapter 2 MECHANISMS ...
Page 20: ...Chapter 3 DISASSEMBLY PROCEDURES ...
Page 58: ...Chapter 4 ASSEMBLY PROCEDURES ...
Page 105: ...Chapter 5 ELECTRONIC CONTROLLERS ...
Page 127: ...Chapter 6 MAINTENANCE ...
Page 149: ...Chapter 7 TROUBLESHOOTING ...