Field
Description
•
3
: The system accepts an incoming call from a
(statically configured) SIP client without this client needing to
have been registered beforehand, if the IP address of the cli-
ent matches the IP address entered under SIP Client IP Ad-
dress. This mode is used by, for example, the MIcrosoft Of-
fice Communications Server and other unified xommunication
servers.
SIP Client IP Address
Only for SIP Client Mode =
3
.
Enter the static local IP address of the SIP client.
Port Number
Only for SIP Client Mode =
3
.
Enter the number of the port to be used for connection.
A 5 digit sequence is possible. For example, port
)+)
must be
entered for connection to a Microsoft Exchange Communication
Server.
Transport Protocol
Only for SIP Client Mode =
3
.
Select the transport protocol for the connection.
Possible values:
•
!5
(default value)
•
5
For example, the
5
protocol must be entered for connection
to a Microsoft Exchange Communication Server.
Fields in the menu Codec Settings
Field
Description
Codec Profile
Select the codec profile to be used if the connection is over a
VoIP line. Codec profiles are configured in the VoIP->Settings-
>Codec Profiles menu.
Fields in the menu Further Settings
Field
Description
Multiple SIP Connec-
tions (Sub-Exchange)
Select whether multilinks shall be allowed from this terminals.
15 Terminals
bintec elmeg GmbH
256
elmeg hybird 120 / hybird 130