16.2 Automatic Route Selection
In the Call Routing->Automatic Route Selection menu, you can set up routes for extern-
al calls in addition to configured line occupancy. Here, bundles released for users can be
selectively assigned to ongoing calls according to the dialled number, or new providers
entered along with their network access prefixes. You then specifically define the routing
for individually created zones for every weekday.
16.2.1 General
In the Call Routing->Automatic Route Selection->General menu, you enable the ARS -
Automatic Route Selection - function and select the desired route level.
Fig. 114:
Call Routing
->
Automatic Route Selection
->
General
The menu Call Routing->Automatic Route Selection->General consists of the following
fields:
Fields in the Basic Settings menu.
Field
Description
ARS
Select whether to enable the ARS performance feature
(Automatic Route Selection).
The function is activated by selecting
;
.
The function is disabled by default.
Routing Stage
Select whether additional routes shall be used if an entered pro-
vider or bundle cannot be accessed.
Possible values:
•
" ;3E
: If the entered provider or selected
bundle is (Call Routing->Automatic Route
Selection->Zones &Routing-> Edit/Add -> Mo-Su ->Rout-
16 Call Routing
bintec elmeg GmbH
272