![BinTec elmeg hybird 120 Reference Manual Download Page 175](http://html1.mh-extra.com/html/bintec/elmeg-hybird-120/elmeg-hybird-120_reference-manual_2752932175.webp)
Field
Description
Enter the number that is to be displayed to the person called
with any outward connection.
This number is not checked.
Signal remote caller
number
Only for Outgoing Signalisation =
4 ; 85
3$ ":;$
and
6: 85 3$
":;$
You can display the number of an external subscriber if it is sig-
nalled.
The function is enabled with
;
.
The function is disabled by default.
Signal fixed out num-
ber
Only for Outgoing Signalisation =
# ': !!
Enter the number that is to be displayed to the person called
with any outward connection.
Fields in the Registrar menu.
Field
Description
Registrar
Enter the DNS name or IP address of the SIP server. A 26 digit
alpha-numeric sequence is possible.
Registrar Port
Enter the number of the port to be used for the connection to
the server. The default value is
)+
. A 5 digit sequence is pos-
sible.
Transport Protocol
Select the transport protocol for the connection.
Possible values:
•
!5
(default value)
•
5
Fields in the STUN menu.
Field
Description
STUN server
Enter the name or the IP address of the STUN server.
STUN = Simple Traversal of User Datagram Protocol (UDP)
bintec elmeg GmbH
13 VoIP
elmeg hybird 120 / hybird 130
157