6.4
System
6.4.2 Site
SitE
Choose your area of operation of the indicator. Choices are:
uSA
,
gb
,
cAn
,
Eu
,
chinA
and
indiA
. This sets the defaults needed for your area
when the indicator is reset. See
.
6.4.3 Display
diSPLAy
Use this to set the following parameters for the display.
dEc.Pt
This configures whether a decimal point or comma is used to
separate whole and fractional numbers.
uPdAte
This configures the number of display refreshes per second.
Choices are
1
,
2
,
5
,
10
and
20
.
m-dASh
If enabled, the display will show dashes during motion.
Site
USA
GB
CAN
EU
CHINA
INDIA
CAUTION: Be sure you follow all local weights and measures regulations.
To reset the default settings affected by the Site selection, choose an alternate Site
selection and press
ZERO
, then re-select the original Site selection.
Display
Dec.Pt
Update
M-dash
C-zero
0.25
0.50
Off
On
1
2
5
10
Decimal
Comma
20
Tot Scl
Off
On
Lowering the update rate can sometimes improve stability of the display in noisy
environments, e.g. vibration or wind.
Summary of Contents for T405S
Page 1: ...AWT35 501638 Issue AA T405S Weight Indicator Service Manual...
Page 2: ...BTEK_T405S_s_en_501638 book...
Page 8: ...8 T405S Indicator Service Manual...
Page 134: ...134 T405S Indicator Service Manual...
Page 147: ...T405S Indicator Service Manual 147 13 7 Outline dimensions...
Page 150: ...150 T405S Indicator Service Manual...
Page 154: ...154 T405S Indicator Service Manual...
Page 155: ......
Page 156: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088...