T405S Indicator Service Manual
97
8.5
Profibus©
8.5 Profibus
©
©
option card. This provides a Profibus connection. See
for information on configuring the indicator and this card.
Figure 8.6 Profibus option card
J2 (DB-9) & TB1 Pinout:
J2 and TB1 provide two connectors to the same Profibus DP interface. J2 is for
standard Profibus DP DB-9 based connector cabling and TB1 is for flying lead wiring
internal to the ZM Indicators enclosure.
+5V and GND are used for external bus termination if the internal S2 termination
resistors are not used.
Profibus-DP
J2 DB9-Female
TB1
Pin No.
Signal
Pin No.
Signal
6
V- (Bus power GND)
6
+5.0 Vdc
5
CAN_LOW
2
Ground
8
Shield
4
-Signal
3
CAN_HI
5
+Signal
Housing V+ (+24VDC)*
1
Shield
3
RTS
S1 switch settings must
all be OFF to operate.
Pin 1