T405S Indicator Service Manual
119
10.5
Transmitting leading zeroes
10.5 Transmitting leading zeroes
A Customer may wish to have the data transmitted with leading zeros and not spaces.
The print format sequence would look like this …
[ = t501
indicates the start of an optional parameter
90 = Z
for leading zero parameters
49 = 1
for use leading zeros
] = t502
indicates the end of the optional parameter
For more examples of editing formats consult
Print tokens, parameters and default
.
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
The above token and function will output the text “Gross”
The above token and function will output the Gross weight value.
GROSS
lb
Characters 5 to 8 will add the leading zeros to the weight transmitted using an optional
parameter. You may need to refer to
for more detail on
necessary character values.
Summary of Contents for T405S
Page 1: ...AWT35 501638 Issue AA T405S Weight Indicator Service Manual...
Page 2: ...BTEK_T405S_s_en_501638 book...
Page 8: ...8 T405S Indicator Service Manual...
Page 134: ...134 T405S Indicator Service Manual...
Page 147: ...T405S Indicator Service Manual 147 13 7 Outline dimensions...
Page 150: ...150 T405S Indicator Service Manual...
Page 154: ...154 T405S Indicator Service Manual...
Page 155: ......
Page 156: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088...