T405S Indicator Service Manual
59
6.4
System
6.4.6 Tare
tArE
Use this item to set the type of tare entry and the tare autoclear functions.
PuShbt
This stands for pushbutton tare. Enable this to use the
TARE
key to tare weight from the scale.
on
is the default value.
EntEr
This stands for keypad entry tare. Enable this and you can
key in a tare value and press
TARE
to activate it during
normal weighing mode.
oFF
is the default.
PrESEt
This stands for preset tare. Preset tare values are entered in
a password protected menu and can be recalled, if this
parameter is enabled.
oFF
is the default value.
tArEcl
This stands for automatic tare clear. Enable this to
automatically clear a tare after a weighment when the weight
falls into the gross zero band.
oFF
is the default value.
hirES
This stands for high resolution tare. If
on
, the indicator does
not round the tare value to the current division size. Choose
on
to enable high resolution tare or
oFF
to disable high
resolution tare.
oFF
is the default value.
Pushbutton and keyboard entry tare can both be set to ON simultaneously. The
TARE
key must be enabled in the
Button
menu.
Tare
Pushbt
Enter
Off
On
Preset
Off
On
Tarecl
Off
On
Off
On
HiRes
Off
On
If preset tare is enabled, pushbutton tare and keyboard entry tare will be disabled
automatically.
Preset Tares are entered in the Supervisor menu. See the User manual.
Summary of Contents for T405S
Page 1: ...AWT35 501638 Issue AA T405S Weight Indicator Service Manual...
Page 2: ...BTEK_T405S_s_en_501638 book...
Page 8: ...8 T405S Indicator Service Manual...
Page 134: ...134 T405S Indicator Service Manual...
Page 147: ...T405S Indicator Service Manual 147 13 7 Outline dimensions...
Page 150: ...150 T405S Indicator Service Manual...
Page 154: ...154 T405S Indicator Service Manual...
Page 155: ......
Page 156: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088...