24
T405S Indicator Service Manual
4
User level menus
StYLE
Choose the style of the date display. Choices are:
MMdd2Y
= Month, Day, 2-digit Year
MMdd4Y
= Month, Day, 4-digit Year
ddMM2Y
= Day, Month, 2-digit Year
ddMM4Y
= Day, Month, 4-digit Year
4.1.3 Site ID
4.1.4 Seal
4.1.5 Archive
To exit the menu, see
.
The seal switch jumper, E7, is located in the top left quadrant of the main PCB. See
T405S jumper and switch settings
. If the jumper is installed, the indicator
is sealed. This means the only the Diagnostic, User, About, Audit and Supervisor
menus can be accessed. Other menus cannot be accessed - the display will flash
SEALEd
.
Site ID
SitE
Use this to enter a Site ID.
The Site ID can be used in a print format. Use the
alphanumeric entry methods described in
enter a Site ID. (maximum 6 digits)
Enter
Site ID
Seal
SEAL
Use this to view the seal status of the indicator.
This is the status of the physical seal jumper inside the
indicator. If the unit is sealed, no changes can be made to
the configuration of the indicator. See the note below.
View Seal
Status
Archive
Port 1
Port 2
USB
ArchiVE
Allows you to print the archived transaction
information.
This item appears only if so
configured in the ADMIN menu.
Summary of Contents for T405S
Page 1: ...AWT35 501638 Issue AA T405S Weight Indicator Service Manual...
Page 2: ...BTEK_T405S_s_en_501638 book...
Page 8: ...8 T405S Indicator Service Manual...
Page 134: ...134 T405S Indicator Service Manual...
Page 147: ...T405S Indicator Service Manual 147 13 7 Outline dimensions...
Page 150: ...150 T405S Indicator Service Manual...
Page 154: ...154 T405S Indicator Service Manual...
Page 155: ......
Page 156: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088...